  • Rugged Micro-TCD Gas Chromatograph
  • 1 to 4 GC Column Oven/Micro-TCD Channels
  • 2 Micro-machined Thermal Conductivity Detectors (TCD) per Channel
  • Designed for Unattended Continuous Operation
  • Most analyses in less than 1 min
  • Integrated 3-Stream Selector
  • Automated Calibrations
  • Fast & Accurate with Low Maintenance
  • Free standing operation with on-board GC Methods
  • Built-in Instrument Diagnostics
  • Easy Chromatography Data System
  • Temperature Control to 0.001°C
  • Pressure Control to 0.001 kPa
  • Ultra Compact and Lightweight (20 X 15 X 10 cm)
  • Approximately 8 kg

Built-in components

Micro-TCD GC: the small, rugged and versatile DPS Micro-TCD gas chromatography systems are built around a micro-machined thermal conductivity detector (TCD). One to four column oven/micro-TCD channels fit inside the same exchangeable cartridge, and each channel holds a column oven, pre-column, analytical column and two micro-TCD detectors.

Each channel also connects injection and backflush valves, for unattended operation and very fast analysis. A built-in stream selector loads each sample stream or the calibration gas automatically. Most analyses finish in seconds, and samples can be injected one straight after another for continuous monitoring.

DPS describes the Micro-TCD GC as a new kind of GC: the separation power of its conventional GC systems in an ultra-small package, so on-line, at-line or laboratory analyses can be run almost anywhere. With four channels, even complex analyses take only seconds.

Micro-TCD GC Channel: each channel is independent and self-contained. Once mounted in the cartridge, it connects to the control module and provides everything a complete GC system needs, including analytical column, pre-column, GC oven, two TCD detectors, sample injector and backflush valve.

Computer & Chromatography Software: connecting a computer gives access to the chromatography and control software for editing methods and sequences. These are stored inside the GC, so once the computer is disconnected the Micro-TCD GC runs unattended and sends results out through its I/O connections. Data is stored inside the GC as well, and can all be accessed when a computer is connected again.

Applications

Industry

  • Oil, gas & petrochemical
  • Analytical & environmental laboratories
  • Transmission & distribution utilities

HV asset application

  • Laboratory gas & liquid samples
  • Transformer insulating oil

Talk to an Expert